  Care Of Your Sammic Vac Packer  

1. Machine must be installed on a flat surface in a cool dry area with an abundant supply of fresh clean air.

2. Before operation machine must be filled with oil to level three quarters of sight glass.

3. Change oil after first 100 hours of use and thereafter every 500 hours or at least every six months.

4. Check oil level daily and top if necessary. Use only oil supplied by your Sammic dealer.

5. Change adhesive tapes on sealing element when it becomes dry and brittle.

6. When machine is filled with oil it must be kept level at all times.

7. The chamber and lid must be kept clean at all times. Do not use abrasive cleaners.

8. No solid particles or liquids must be allowed enter the exhaust outlet.

9. For full instructions on care and use of your Sammic vacuum packer refer to users manual.